POLO grating made up of cross-laid steel strips connected to the frame. according to customer grid supply:
A typical data grid floor POLO shown in Table.
Ordinal numb. | The height of the grid | Suporting lamella
h1*b1 mm |
The dividing lamella mm
h2*b1 mm |
Box
h*b mm |
Step of lamella
t mm |
G
kg/m2 |
Spacing of supports T [mm] | ||||||||
700 | 900 | 1000 | 1100 | 1300 | 1500 | 1700 | 1900 | 2000 | |||||||
Permitted continuously load q(kN/m²) on the suface | |||||||||||||||
1 | 45 | 45*2 | 40*2 | 45*3 | 22 | 64,5 | 48,0 | 22,5 | 16,2 | 12,1 | 7,1 | 4,4 | 2,9 | 1,9 | 1,6 |
2 | 45 | 45*2 | 40*2 | 45*3 | 30 | 49,5 | 41,6 | 19,3 | 14,0 | 10,4 | 6,1 | 3,8 | 2,5 | 1,7 | 1,4 |
3 | 40 | 40*2 | 35*2 | 40*3 | 40 | 34,5 | 27,8 | 12,9 | 9,3 | 6,9 | 4,1 | 2,6 | 1,7 | 1,12 | |
4 | 35 | 35*3 | 35*3 | 35*3 | 30 | 56,8 | 26,8 | 12,4 | 8,9 | 6,6 | 3,8 | 2,3 | 1,4 | ||
5 | 30 | 33*2 | 30*3 | 30*3 | 30 | 48,7 | 21,0 | 9,9 | 7,1 | 5,2 | 3,0 | 1,8 | 1,1 | ||
6 | 30 | 30*2 | 30*2 | 30*3 | 30 | 34,6 | 14,8 | 6,8 | 4,9 | 3,6 | 2,1 | 1,2 | |||
7 | 30 | 30*2 | 25*2 | 30*3 | 30 | 32,2 | 12,7 | 5,9 | 4,2 | 3,1 | 1,8 | 1,1 | |||
8 | 25 | 25*2 | 20*2 | 25*3 | 22 | 34,5 | 8,5 | 3,9 | 2,7 | 2,0 | 1,1 | ||||
9 | 25 | 25*2 | 20*2 | 25*3 | 30 | 26,5 | 8,0 | 3,6 | 2,6 | 1,9 | 1,1 | ||||
10 | 25 | 25*2 | 20*2 | 25*3 | 40 | 20,8 | 7,4 | 3,4 | 2,4 | 1,8 | 1,0 |
q= Permitted continuously load on the suface whitout box for a range of support L.
G= mass of the grid without surface protection